Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NPL, UK, and the BIPM in low-energy x-rays

A key comparison has been made between the air-kerma standards of the NPL, UK and the BIPM in the low-energy x-ray range. The results indicate a progressive drift of the NPL standard, now lower than the BIPM standard by around 1 part in 102. The expanded uncertainty (k = 2) of the comparison is 4.2... Full description

Contained in: Metrologia Vol. 56, No. 1A Technical Supplement 2019 (2019), p. 06004/1-11
Journal Title: Metrologia
Fulltext access:
Availability is being checked...
Interlibrary loan: Check possibility for interlibrary loan
Links: Additional Link (dx.doi.org)
ISSN: 1681-7575
Additional Keywords: ROENTGENSTRAHL
DOI: 10.1088/0026-1394/56/1A/06004
Notes: Copyright: Metadaten: TEMA, Copyright WTI-Frankfurt-digital GmbH
Copyright: (C) Alle Rechte beim Herausgeber
Physical Description: 11 Seiten
ID (e.g. DOI, URN): 10.1088/0026-1394/56/1A/06004
PPN (Catalogue-ID): WTI06401360X
Note: WTI TEMA DB
more publication details ...

Associated Publications/Volumes

  • Associated records are being queried...
more (+)
Internes Format
LEADER 01728nma a2200313 c 4500
001 WTI06401360X
003 DE-601
005 20190923003551.0
007 cr uuu---uuuuu
008 190923s2019 000 0 und d
024 7 |a 10.1088/0026-1394/56/1A/06004  |2 doi 
028 5 2 |a TEMA1937_wti_pica 
035 |a (DE-599)WTI20190436349 
040 |b ger  |c GBVCP 
084 |a A  |2 FIZTtc 
084 |a 3IFT  |a 3IB  |a 3IDO  |2 FON2006 
245 0 0 |a Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NPL, UK, and the BIPM in low-energy x-rays  |h Elektronische Ressource 
300 |a Online-Ressource  |a 11 Seiten 
500 |a Copyright: Metadaten: TEMA, Copyright WTI-Frankfurt-digital GmbH 
500 |a Copyright: (C) Alle Rechte beim Herausgeber 
520 |a A key comparison has been made between the air-kerma standards of the NPL, UK and the BIPM in the low-energy x-ray range. The results indicate a progressive drift of the NPL standard, now lower than the BIPM standard by around 1 part in 102. The expanded uncertainty (k = 2) of the comparison is 4.2 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. [Copyright IOP Institute of Physics Publishing. Reproduced with permission.] 
653 4 |a ROENTGENSTRAHL 
773 0 8 |i In  |t Metrologia  |g Vol. 56, No. 1A Technical Supplement 2019 (2019), p. 06004/1-11  |q 56:1A Technical Supplement 2019<06004/1-11  |x 1681-7575  |x 1681-7575 
856 4 0 |u https://dx.doi.org/10.1088/0026-1394/56/1A/06004 
912 |a GBV_WTI 
950 |a X-Strahl  |2 DE-601 
950 |a BIPM Standard  |a expanded uncertainty  |2 DE-601 
951 |a AR 
952 |d 56  |j 2019  |e 1A Technical Supplement 2019  |h 06004/1-11